PRODUCTS
PATIENT MONITOR
M40
Comprehensive Solution for your needs in Critical
and Intermediate Care
- Display : High resolution 10.4" Color LCD Touch Screen
- Number of Traces : 4~12 waveforms
- Measurement Parameter
- * Basic : 3/5 Lead ECG, SpO2(Medtronic, Mediana), NIBP(AND), Resp, Temp, HR/RR
- * Option : 12 Lead ECG(Glasgow algorithm), EtCO2(Respronics, Kingst), 2 IBP
- EWS(Early Warning Score) : NEWS(National Early Warning Score), NEWS2 and Custom
- OxyCRG
- * Combination of three trend waves, Beat-to-beat heart Rate, Spo2 and Respiration, mainly used in neonatal monitoring
- Freeze : Current data and previous 2 minutes
- Communication
- * Infoware G : Intuitive and comprehensive CMS(Central monitoring system)
- * Infoware X : Highly reliable dedicated communication module, to connect via Wi-if, WCDMA or LAN
Intended Use for the M40
The monitor is intended to be used to monitor electrocardiography (ECG), heart rate (HR), noninvasive blood pressure (NIBP) - systolic, diastolic and mean arterial pressures, functional arterial oxygen saturation (SpO2), pulse rate (PR), respiration rate (RR), capnography (EtCO2 and InCO2), Invasive blood pressure (IBP) and temperature (TEMP) for adult, pediatric and neonatal patients in all areas of a hospital and hospital-type facilities. Monitor users should be skilled at the level of a technician, doctor, nurse or medical specialist. The M40 is suitable for continuous operation.
Note: Hospital use typically includes such as general care floors, operating rooms, special procedure areas, intensive and critical care area, within the hospital. Hospital-type facilities include ambulance, physician office-based facilities, sleep labs, skilled nursing facilities, surgical centers, and sub-acute care centers.
Note: The medically skilled and trained user can be clinicians like doctors and nurses who know how to take and interpret a patient’s vital signs. These clinicians must take direct responsibility for the patient’s life. This can include care-givers or medically trained interpreters who are authorized under the appropriate clinical facility procedures to support patient care. Any inappropriate setting, especially the alarm limit or alarm notification settings, can lead to a hazardous situation that injures the patient, harms the patient, or threatens the patient’s life. This equipment should only be operated by trained users who can adjust the settings of the vital signs monitor.
Note: Hospital use typically includes such as general care floors, operating rooms, special procedure areas, intensive and critical care area, within the hospital. Hospital-type facilities include ambulance, physician office-based facilities, sleep labs, skilled nursing facilities, surgical centers, and sub-acute care centers.
Note: The medically skilled and trained user can be clinicians like doctors and nurses who know how to take and interpret a patient’s vital signs. These clinicians must take direct responsibility for the patient’s life. This can include care-givers or medically trained interpreters who are authorized under the appropriate clinical facility procedures to support patient care. Any inappropriate setting, especially the alarm limit or alarm notification settings, can lead to a hazardous situation that injures the patient, harms the patient, or threatens the patient’s life. This equipment should only be operated by trained users who can adjust the settings of the vital signs monitor.
Accessories
Cut down on downtime. Find replacement parts and additional products to keep you up and running.
-
Only with Nellcor Option Nellcor Oximax Reusable Sensor (DS100A)PART # : A0012-0
-
AC Power Cord(US) 110VPART # : A0018-1
-
Only with Nellcor Option_Nellcor Extension Cable (DOC10)PART # : A0029-0
-
AC Power Cord(UK)PART # : A0106-0
-
_TRAS-2252 Temperature Probe(400 series Skin Type)_PART # : A0133-1
-
_Temp Probe YSI-400(Rectal)_PART # : A0146-1
-
Loflo CO2 nasal cannula w_O2-Pediatric Back SidePART # : A0208-0
-
Loflo CO2 nasal cannula w_O2-Pediatric Front SidePART # : A0208-0
-
Cable holding clipsPART # : A0227-0
-
Mediana SpO2 Extension cable(MEX03) only for Mediana SpO2)PART # : A0266-0
-
SpO2 Extension Cable(BCI) RCP-006(3M_14P)PART # : A0266-0
-
_ECG 12-Lead Wire and Trunk Cable (Snap_US)PART # : A0325-1
-
_ECG 12-Lead Wire and Trunk Cable (Snap_EU)PART # : A0326-1
-
ECG 5Lead, Snap, USPART # : A0329-1
-
ECG 5Lead, Snap, EUPART # : A0330-1
-
_ECG 5-Lead Wire and Trunk Cable (Grab_US)PART # : A0331-1
-
_ECG 5-Lead Wire and Trunk Cable (Grab_EU)PART # : A0332-1
-
_ECG 3-Lead Wire and Trunk Cable (Grab_US)PART # : A0335-3
-
_ECG 3-Lead Wire and Trunk Cable (Grab_EU)PART # : A0336-3
-
Kingst Sidestream Water Filter Back SidePART # : A0701-0
-
Kingst Sidestream Water Filter Front SidePART # : A0701-0
-
Kingst Sidestream Module ReceptaclePART # : A0702-0
-
Kingst Sidestream Sampling Line Back SidePART # : A0703-0
-
Kingst Sidestream Sampling Line Front SidePART # : A0703-0
-
Kingst Sidestream Airway AdapterPART # : A0704-0
-
Kingst Mainstream Adult Airway Adapter Back SidePART # : A0706-0
-
Kingst Mainstream Adult Airway Adapter Front SidePART # : A0706-0
-
Kingst Mainstream Infant Airway Adapter Back SidePART # : A0707-0
-
Kingst Mainstream Infant Airway Adapter Front SidePART # : A0707-0
-
_AND Cuff 7.5-10.5cm NEONATAL (TM-9157)PART # : A0921-0
-
_AND Cuff 5-7.5cm NEONATAL (TM-9156)PART # : A0922-0
-
_AND Cuff 4-5cm NEONATAL (TM-9155)PART # : A0923-0
-
AND HOSE 3.5M ADULTS&PEDIATRICPART # : A0932
-
AND CUFF 8.5-13CM NEONATAL(TM-9158)PART # : A0933-0
-
_AND Connector Hose 1.5m Adults_PediatricPART # : A0934-0
-
AND CUFF 12-17cm (CUF-KS-SS(R))PART # : A0974-0
-
AND CUFF 16-24CM (CUF-KS-SA(R)PART # : A0975-0
-
AND CUFF 31-45CM (CUF-KS-LA(R))PART # : A0976-0
-
AND CUFF 42-50CM (CUF-KS-LL(R))PART # : A0977-0
-
AND CUFF 22-32CM (CUF-KS-A(R))PART # : A0978-0
-
Side Stream LoFlo Sidestream CO2 ModulePART # : M0018-1
-
Main Stream CAPNOSTAT 5 CO2 SensorPART # : M0019-1
-
Kingst Capno-M Mainstream ModulePART # : M0083-0
-
Kingst Capno-S+ Sidestream ModulePART # : M0084-0